Sprinkler Application Rate Explained

Learn how to calculate sprinkler application rate from catch-can depths and a timed zone test.

Application rate tells you how quickly a sprinkler zone applies water, based on measured depth over time. Measure each zone separately: zones that look similar can still have different rates.

Measure average catch depth

Place at least four identical containers across one zone, run it for a known duration, and measure the depth collected in each container. The average is the sum of the readings divided by the number of containers. Include zero readings in both the sum and the count.

Convert depth and duration into a rate

When depth is in millimeters and duration is in minutes, application rate in millimeters per hour = average depth × 60 ÷ duration.

The factor 60 converts minutes to an hour. Keep the depth units consistent: if the collected depth is in inches, the resulting rate is inches per hour.

Worked example: G001

Suppose four containers collect 5, 6, 5, and 4 mm during a 15-minute test. Their mean depth is (5 + 6 + 5 + 4) ÷ 4 = 5 mm. The rate is 5 × 60 ÷ 15 = 20 mm/h.

This example matches the Sprinkler Run G001 reference vector. A zero reading would also count as one of the readings; do not remove a dry container before calculating the mean.

Application rate and uniformity answer different questions

The average application rate summarizes how much water the zone applied over the test. Low-quarter uniformity describes how evenly the measured water was distributed among containers. A mean rate alone does not show where a zone has dry or wet spots.

Use the measured rate with a target depth you choose to calculate runtime. Sprinkler Run does not prescribe the target depth or a watering schedule.