Free sprinkler calculator
Catch-can test calculator
Enter the test duration and water depth from each container. The calculator keeps zero readings in the average and needs at least four readings.
How to use a catch-can test
Place identical straight-sided containers across one sprinkler zone and run it for a measured duration. Measure the collected water depth in each container, then enter every reading, including any zeros.
Average depth is the sum of readings divided by their count. Application rate is average depth × 60 ÷ test duration. Low-quarter uniformity compares the average of the lowest quarter of readings with the overall average; a higher value means the readings were more even.
If you enter a target depth, runtime is calculated from that target and the measured application rate. This is a homeowner calculator, not a certified irrigation audit.