Free sprinkler calculator

Catch-can test calculator

Enter the test duration and water depth from each container. The calculator keeps zero readings in the average and needs at least four readings.

Water depth readings (mm)

Enter at least four readings. A zero is a valid reading.

Use identical straight-sided containers and measure the water depth in each one. More readings usually give a more representative picture of the zone.

How to use a catch-can test

Place identical straight-sided containers across one sprinkler zone and run it for a measured duration. Measure the collected water depth in each container, then enter every reading, including any zeros.

Average depth is the sum of readings divided by their count. Application rate is average depth × 60 ÷ test duration. Low-quarter uniformity compares the average of the lowest quarter of readings with the overall average; a higher value means the readings were more even.

If you enter a target depth, runtime is calculated from that target and the measured application rate. This is a homeowner calculator, not a certified irrigation audit.